| The sequence of the baths
is as follows: developer, intermediate rinse,
fixer, final rinse.
Machine operation and film insertion are
done in daylight - no need for darkroom
operation.
A film inspection station is possible just
ahead of the take-up device.
The chemistry temperature and the processor
speed are adjustable. The varioflott
requires a three-phase current,
400 V / 16 A, as well as cold water connection
and drain. The water is tempered in the
processor.
The automatically replenishment system,
which is adjustable, ensures consistency
of individual baths. The level of the replenishment
supply containers is monitored and displayed.
The varioflott is a very
user friendly, convenient automatic processor,
which is environment friendly through efficient
energy usage, coupled with the lowest water
consumption possible, whilst still achieving
processing to archival standards.
|